H102 Heat Exchanger Service Unit

H102 Heat Exchanger Service Unit

A bench mounted panel with integral electrical console providing services for any of the optional heat exchangers in the range. Temperature controlled hot water is provided and the hot and cold flow is controlled and measured using variable area flowmeters.

The optional heat exchangers are connected using non-drip, self sealing couplings. Standard instrumentation consists of up to 12 thermocouples, a digital panel meter, and two flowmeters. Optional data acquisition is available for attachment to this unit.

H102 Heat Exchanger Service Unit

A bench mounted heat exchanger service unit comprising a reinforced plastic instrument panel with electric water heater and circulating pump providing temperature controlled hot water from self sealing quick release couplings. Controlled and measured cold water is taken from the local supply.

Internal electric and mechanical safety devices to allow for unsupervised operation by students.

Instrumentation to measure up to 12 temperatures and the relevant flow rates of the hot and cold fluids through the heat exchanger under test

10 Optional Heat Exchangers available:-

For detailed descriptions and experimental capabilities refer to individual data sheets for each optional heat exchanger.

Electrical:

A: 220-240 Volts, Single Phase, 50Hz (With earth/ground).

    Line current up to10A at 230v

  OR

B: 110-120 Volts, Single Phase, 60Hz (With earth/ground).

    Line current up to 20A at 110v         

Water:  

3 litres m-1 at a minimum of 10m head.

Open drain for this flow rate.